Author
Updated
13 Mar 2025This document lists the supported rail kits for Lenovo ThinkSystem, ThinkAgile, and ThinkEdge servers and allows you to compare the specifications.
How to search
The web page initially displays all available rail kits. Scroll horizontally to view all the controllers. You can also use the search or filter functions to further narrow the results.
To search: Enter a search term and click Search, or click Add Filter to perform more advanced searching. For information on how to view, rearrange and export the data, click the Help link.
Option part number
| 4XF7A99129 | 4XF7A99130 | 4XF7A99131 | 4XF7A97373 | 4XF7A97370 | 4XF7A97379 | 4XF7A97375 | 4XF7A97371 | 4XF7A89443 | 4XF7A16545 | 4XF7A90718 | 4XF7A83645 | 4XF7A86615 | 4XF7A86616 | 4M17A13564 | 4XF7A81940 | 4XF7A81942 | 4XF7A81943 | 4XF7A81941 | 4XF7A78620 | 4M17A69408 | 4M17A61253 | 4XF7A12864 | 4XF7A12865 | 4M17A37611 | 4M17A11754 | 4M17A11755 | 4M17A11756 | 4M17A11757 | 4M17A11758 | 4M17A37605 | 4M17A12785 | 4M17A37105 | 4M17A11683 | 7M27A05702 | 7M27A05701 | 7M27A05700 | 4M17A07274 | 4M17A07281 |
Description
| ThinkSystem Toolless Stab- in Slide Rail Kit V3 | ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 1U CMA | ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 2U CMA | ThinkSystem Toolless Slide Rail Kit V4 with 1U CMA | ThinkSystem Toolless Slide Rail Kit V4 | ThinkSystem Toolless Friction Rail V4 | ThinkSystem Advanced Toolless Slide Rail Kit V4 with 1U CMA | ThinkSystem Advanced Toolless Slide Rail Kit V4 | ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 1U CMA | ThinkSystem Toolless Fixed Rail Kit | ThinkEdge 1000mm Friction Rail Kit v2 | ThinkSystem Enclosure Universal Short Rack Rail Kit | ThinkSystem SR850 V3 Slide Rail | ThinkSystem SR860 V3 Slide Rail | ThinkSystem Toolless Friction Rail v2 | ThinkEdge 1000mm Friction Rail Kit | ThinkEdge 600mm Ball Bearing Rail Kit | ThinkEdge SE450 550mm Ball Bearing Rail Kit | ThinkEdge 2-Post Friction Rail Kit | ThinkSystem ST50 Series / ST250 Series Rack Mount Kit | ThinkSystem SR670 V2/ SR675 V3 Toolless Slide Rail | ThinkSystem DA240 Static Rail Kit | ThinkSystem SR860 V2 2U Toolless Slide Rail | ThinkSystem SR850 V2 Rail Kit | ThinkSystem Toolless Friction Rail Kit | ThinkSystem Toolless Slide Rail Kit v2 | ThinkSystem Toolless Slide Rail Kit v2 Enhanced | ThinkSystem Toolless Slide Rail Kit v2 with 2U CMA | ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 2U CMA | ThinkSystem Toolless Slide Rail Kit v2 with 1U CMA | ThinkSystem Enclosure Short Rack Rail Kit | ThinkSystem ST50/ST250 Rack Mount Kit | ThinkSystem Friction 2-Post Screw-in Rail Kit | 1U and 2U Slide Rail | ThinkSystem Toolless Slide Rail | ThinkSystem Toolless Slide Rail Kit with 1U CMA | ThinkSystem Toolless Slide Rail Kit with 2U CMA | ThinkSystem Screw-in Slide Rail | ThinkSystem Screw-in Slide Rail Kit with 1U CMA |
Announcement date
| 2024-09-03 | 2024-09-03 | 2024-09-03 | 2024-09-03 | 2024-09-03 | 2024-06-04 | 2019-12-02 | 2025-03-12 | 2023-07-18 | 2023-01-12 | 2023-01-12 | 2022-06-21 | 2024-11-29 | 2022-03-15 | 2022-03-15 | 2022-03-15 | 2022-03-01 | 2021-04-06 | 2021-04-06 | 2020-10-13 | 2020-10-13 | 2020-09-22 | 2020-05-05 | 2020-05-05 | 2020-05-05 | 2020-05-05 | 2020-05-05 | 2019-08-20 | 2018-11-06 | 2019-07-23 | 2018-07-03 | 2017-07-12 | 2017-07-12 | 2017-07-12 | 2017-07-12 | 2017-07-12 | |||
Withdrawal date
| |||||||||||||||||||||||||||||||||||||||
Availability
| Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available |
Rail type
| Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Half-out slide rail (friction), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | L Shelf static rail, toolless installation | Full-out slide rail (friction), toolless installation | Half-out slide rail (friction), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Half-out slide rail (friction), toolless installation | Full-out slide rail (friction), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), for 300 mm depth chassis only, toolless installation | Half-out slide rail (friction), screw-in installation | Rack Mount Kit (Included CMA) | Full-out slide rail (ball bearing), toolless installation | L-shelf, 2U | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Half-out slide rail (friction), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Half-out slide rail (friction), toolless installation | Rack Mount Kit (Included CMA) | Half-out slide rail (friction), screw-in installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), toolless installation | Full-out slide rail (ball bearing), tool installation | Full-out slide rail (ball bearing), tool installation |
Mounting type
| Stab-in sliding | Stab-in sliding | Stab-in sliding | Stab-in sliding | Stab-in sliding | Stab-in static | Stab-in sliding | Stab-in sliding | Drop-in | L-bracket static | Stab-in static | Stab-in static | Stab-in sliding | Stab-in sliding | Stab-in static | Stab-in static | Stab-in sliding | Stab-in sliding | Stab-in static | Tower to rack | Drop-in | L-bracket static | Drop-in | Drop-in | Stab-in static | Drop-in | Drop-in | Drop-in | Drop-in | Drop-in | Stab-in static | Tower to rack | Stab-in static | Drop-in | Drop-in | Drop-in | Drop-in | Drop-in | Drop-in |
Supported rack type
| Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack | Four-post IBM and Lenovo standard rack | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack | Four-post 600 mm depth standard rack | Four-post custom cabinet | 2-post rack, maximum distance of the mounting flange is 279.4 mm (11 inches) | Four-post IBM and Lenovo standard rack, complying with the IEC standard | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | 2-post rack, EIA standard- compliant (3-inch to 8-inch) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) | Four-post IBM and Lenovo standard rack, complying with the IEC standard (2) |
Service in rack
| Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | No | No | Yes | Yes | No | Yes (SE450 only) | Yes (SE450 only) | Yes | No | No | Yes | No | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | No | No | No | Yes | Yes | Yes | Yes | Yes | Yes |
Cable Management Arm (CMA) part number
| For SR630 V2, SR635 V3, SR645 V3, SR630 V3: 7M27A05699 For SR650 V2, SR655 V3, SR665 V3, SR650 V3: 7M27A05698 | CMA is included in the Rail Kit option part number | CMA is included in the Rail Kit option part number | CMA is included in the Rail Kit option part number | 7M27A05699 and 7M27A05698 | No CMA support | CMA is included in the Rail Kit option part number | 7M27A05699 and 7M27A05698 | CMA is included in the Rail Kit option part number | No CMA support | No CMA support | No CMA support | 4XF7A86617 | 4XF7A86617 | No CMA support | No CMA support | No CMA support | No CMA support | No CMA support | CMA is included in the Rail Kit option part number | No CMA support | No CMA support | CMA is included in the Rail Kit option part number | CMA is included in the Rail Kit option part number | No CMA support | For SR645, SR645 V3, SR630 V2, SR630 V3, and SR635 V3: 7M27A05699; For SR665, SR665 V3, SR650 V2, SR650 V3, and SR655 V3: 7M27A05698 | 7M27A05698 | CMA is included in the Rail Kit option part number | CMA is included in the Rail Kit option part number | CMA is included in the Rail Kit option part number | No CMA support | CMA is included in the Rail Kit option part number | No CMA support | No CMA support | For SR530, SR570, SR630, and SR635: 7M27A05699; For SR550, SR590, SR650, SR655, SR850, and SR850P: 7M27A05698 | CMA is included in the Rail Kit option part number | CMA is included in the Rail Kit option part number | For SR530, SR570, and SR630: 4M17A07276; For SR550, SR590, SR650, and SR850: 4M17A07275 | CMA is included in the Rail Kit option part number |
1U power distribution unit (PDU) support
| Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
0U PDU support
| Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Yes | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Yes | Limited support (2) | Limited support (2) | Yes | Limited support (2) | NA | NA | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Yes | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Yes | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) | Limited support (2) |
Supported mounting holes
| Square or round | Square or round | Square or round | Square or round | Square or round | Square or round | Square, round, or threaded | Square, round, or threaded | Square, round, or threaded | Square or round | Square or round | Square, round, or threaded | Square or round | Square or round | Square or round | Square or round | Square or round | Square or round | Square, round, or threaded | Square or round | Square (9.2 to 9.5mm), round (diameter 7.1 mm), or threaded (tool kit is required) | EIA 4-post rack 9.5 mm square hole; 7.1 mm round hole; and Lenovo 9.2 mm square hole 4-post rack. | Square or round | Square or round | Square or round | Square or round | Square, round, or threaded | Square or round | Square, round, or threaded | Square or round | Square or round | Square or round | Square, round, or threaded | Square or round | Square or round | Square or round | Square or round | Square, round, or threaded | Square or round |
Thickness of mounting flanges
| 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | Maximum width of the mounting flange is 279.4 mm (11 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) | 2.0 to 3.3 mm (0.08 to 0.13 inches) |
Supported distance between front and rear mounting flanges (3)
| 635 to 812.8 mm (25 to 32 inches) | 635 to 812.8 mm (25 to 32 inches) | 635 to 812.8 mm (25 to 32 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 635 to 812.8 mm (25 to 32 inches) | 612.8 to 774 mm (24.12 to 30.47 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 355.6 to 609.6 mm (14 to 24 inches) | 635 to 812.8 mm (25 to 32 inches) | 609.6 to 902 mm (24 to 35.75 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 400 to 500 mm (15.74 to 19.68 inches) | 270 to 310 mm (10.63 to 12.20 inches) | N/A | 665 to 900 mm (26.18 to 35.43 inches) | 609.6 to 812.8 mm (24 to 32 inches) | 565 to 914 mm (22.24 to 35.98 inches) | 609.6 to 812.8 mm (24 to 32 inches) | 609.6 to 762 mm (24 to 30 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 812.8 mm (24 to 32 inches) | 635 to 812.8 mm (25 to 32 inches) | 609.6 to 812.8 mm (24 to 32 inches) | 635 to 812.8 mm (25 to 32 inches) | 609.6 to 812.8 mm (24 to 32 inches) | 355.6 to 609.6 mm (14 to 24 inches) | 665 to 900 mm (26.18 to 35.43 inches) | N/A | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 863.6 mm (24 to 34 inches) | 609.6 to 812.8 mm (24 to 32 inches) | 609.6 to 812.8 mm (24 to 32 inches) |
Rail length (4)
| 820 mm (32.28 inches) | 820 mm (32.28 inches) | 820 mm (32.28 inches) | 851.5 mm | 771.5 mm | 751.2 mm | 851.5 mm | 771.5 mm | 820 mm (32.28 inches) | 612.8 mm (24.1 inch) | 751 mm (29.56 inches) | 484 mm | 918 mm (36.14 inches) | 885.4 mm (34.9 inches) | 751.2 mm | 751 mm (29.56 inches) | 454 mm (17.87 inches) | 315 mm (14.40 inches) | 484 mm (19.06 inches) | 792 mm | 768 mm (30.24 inches) | 600 mm (23.6 inches) | 885.4 mm (34.9 inches) | 901.7 mm (35.5 inches) | 751.2 mm (29.57 inches) | 740 mm (29.13 inches) | 740 mm (29.13 inches) | 820 mm (32.28 inches) | 820 mm (32.28 inches) | 820 mm (32.28 inches) | 484 mm | 792 mm | 484 mm | 807 mm (31.77 inches) | 730 mm (28.74 inches) | 818 mm (32.20 inches) | 818 mm (32.20 inches) | 836.8 mm (32.94 inches) | 836.8 mm (32.94 inches) |
HS350X V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD530 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD530 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SD530 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD535 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SD535 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD550 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SD550 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD630 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SD630 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD650 Support
| No | No | No | No | No | No | No | No | No | SD650 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD650 V2 Support
| No | No | No | No | No | No | No | No | No | SD650 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD650 V3 Support
| No | No | No | No | No | No | No | No | No | SD650 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD650-I V3 Support
| No | No | No | No | No | No | No | No | No | SD650-I V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD650-N V2 Support
| No | No | No | No | No | No | No | No | No | SD650-N V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD650-N V3 Support
| No | No | No | No | No | No | No | No | No | SD650-N V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD665 V3 Support
| No | No | No | No | No | No | No | No | No | SD665 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SD665-N V3 Support
| No | No | No | No | No | No | No | No | No | SD665-N V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SE350 Support
| No | No | No | No | No | No | No | No | No | No | No | SE350 | No | No | No | No | No | No | No | No | No | No | No | No | SE350 | No | No | No | No | No | SE350 | No | SE350 | SE350 | No | No | No | No | No |
SE350 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | SE350 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SE350 V2 | SE350 V2 | No | No | No | No | No |
SE360 V2 Support
| No | No | No | No | No | No | No | No | No | No | SE360 V2 | No | No | No | No | SE360 V2 | SE360 V2 | No | SE360 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SE450 Support
| No | No | No | No | No | No | No | No | No | No | SE450 | No | No | No | No | SE450 | SE450 | SE450 | SE450 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SE455 V3 Support
| No | No | No | No | No | No | No | No | No | No | SE455 V3 | No | No | No | No | No | SE455 V3 | No | SE455 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SN550 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SN550 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SN850 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR150 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR150 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR150 | No | SR150 | No | No | No | No | No | No |
SR250 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR250 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR250 | No | SR250 | No | No | No | No | No | No |
SR250 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR250 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR250 V2 | No | SR250 V2 | No | No | No | No | No | No |
SR250 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR250 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR250 V3 | No | SR250 V3 | No | No | No | No | No | No |
SR530 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR530 | SR530 | No | SR530 | SR530 |
SR550 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR550 | No | SR550 | SR550 | No |
SR570 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR570 | SR570 | No | SR570 | SR570 |
SR590 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR590 | No | SR590 | SR590 | No |
SR630 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR630 | SR630 | No | SR630 | SR630 |
SR630 V2 Support
| SR630 V2 | SR630 V2 | No | No | No | No | No | No | SR630 V2 | No | No | No | No | No | SR630 V2 | No | No | No | No | No | No | No | No | No | No | SR630 V2 | SR630 V2 | No | No | SR630 V2 | No | No | No | No | No | No | No | No | No |
SR630 V3 Support
| SR630 V3 | SR630 V3 | No | No | No | No | No | No | SR630 V3 | No | No | No | No | No | SR630 V3 | No | No | No | No | No | No | No | No | No | No | SR630 V3 | SR630 V3 | No | No | SR630 V3 | No | No | No | No | No | No | No | No | No |
SR630 V4 Support
| No | No | No | SR630 V4 | SR630 V4 | SR630 V4 | SR630 V4 | SR630 V4 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR635 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR635 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR635 | SR635 | No | No | No |
SR635 V3 Support
| SR635 V3 | SR635 V3 | No | No | No | No | No | No | SR635 V3 | No | No | No | No | No | SR635 V3 | No | No | No | No | No | No | No | No | No | No | SR635 V3 | SR635 V3 | No | No | SR635 V3 | No | No | No | No | No | No | No | No | No |
SR645 Support
| No | No | No | No | No | No | No | No | SR645 | No | No | No | No | No | SR645 | No | No | No | No | No | No | No | No | No | No | SR645 | SR645 | No | No | SR645 | No | No | No | No | No | No | No | No | No |
SR645 V3 Support
| SR645 V3 | SR645 V3 | No | No | No | No | No | No | SR645 V3 | No | No | No | No | No | SR645 V3 | No | No | No | No | No | No | No | No | No | No | SR645 V3 | SR645 V3 | No | No | SR645 V3 | No | No | No | No | No | No | No | No | No |
SR650 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR650 | No | SR650 | SR650 | No |
SR650 V2 Support
| SR650 V2 | No | SR650 V2 | No | No | No | No | No | No | No | No | No | No | No | SR650 V2 | No | No | No | No | No | No | No | No | No | No | SR650 V2 | SR650 V2 | SR650 V2 | SR650 V2 | No | No | No | No | No | No | No | No | No | No |
SR650 V3 Support
| SR650 V3 | No | SR650 V3 | No | No | No | No | No | No | No | No | No | No | No | SR650 V3 | No | No | No | No | No | No | No | No | No | No | SR650 V3 | SR650 V3 | SR650 V3 | SR650 V3 | No | No | No | No | No | No | No | No | No | No |
SR650 V4 Support
| No | No | No | No | SR650 V4 | SR650 V4 | No | SR650 V4 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR650a V4 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR655 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR655 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR655 | No | SR655 | No | No |
SR655 V3 Support
| SR655 V3 | No | SR655 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR655 V3 | No | SR655 V3 | No | No | No | No | No | No | No | No | No | No | No |
SR665 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR665 | No | No | No | No | No | No | No | No | No | No | SR665 | SR665 | SR665 | SR665 | No | No | No | No | No | No | No | No | No | No |
SR665 V3 Support
| SR665 V3 | No | SR665 V3 | No | No | No | No | No | No | No | No | No | No | No | SR665 V3 | No | No | No | No | No | No | No | No | No | No | SR665 V3 | SR665 V3 | SR665 V3 | SR665 V3 | No | No | No | No | No | No | No | No | No | No |
SR670 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR670 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR670 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR675 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR675 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR680a V3 Support
| No | No | No | No | No | No | No | No | No | SR680a V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR685a V3 Support
| No | No | No | No | No | No | No | No | No | SR685a V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR780a V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR850 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR850 | No | SR850 | SR850 | No |
SR850 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR850 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR850 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | SR850 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR850P Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR850P | No | SR850P | No | No |
SR860 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR860 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | SR860 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR860 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | SR860 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR950 Support
| No | No | No | No | No | No | No | No | No | SR950 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SR950 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
ST250 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | ST250 | No | No | No | No | No | No | No |
ST250 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | ST250 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
ST250 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | ST250 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
ST45 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | ST45 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
ST50 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | ST50 | No | No | No | No | No | No | No |
ST50 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | ST50 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
ST50 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | d | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
ST550 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
ST650 V2 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | ST650 V2 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
ST650 V3 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | ST650 V3 | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
SC750 V4 Support
| No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
Notes
- There are no CMA mounting brackets preinstalled on the rail. The CMA mounting brackets are contained in the CMA option kit package. Before installing the CMA, you need to install the CMA mounting brackets first. For detailed instructions, refer to the documentation that comes with the CMA option kit.
- If you want to install the rails and a 0U PDU into the same rack, the rack must meet the height and depth requirements. See the sections below for details, Rack cabinets with parallel 0U PDUs and Rack cabinets with perpendicular 0U PDUs.
- For best performance, it is recommended that you install the rails to the racks with a 719-mm distance (28.31-inch, Lenovo rack default distance) between the front and rear mounting flanges.
- The rail length refers to the distance measured when the rail is not extended.
Rack cabinets with parallel 0U PDUs
The table below lists the rail kits that are supported in each rack cabinet when 0U PDUs are installed in an orientation that is parallel to the sidewalls of the cabinet (sockets facing the rear of the rack). The table also lists the horizontal clearances A and B, as shown in the figure.
Figure 1. Rack cabinets with parallel 0U PDUs
Rack MT | Rack depth | Rail selection | A 1 | B 2 |
---|---|---|---|---|
9307 | 1000 mm (39.37 inches) |
Supporting CMA and PDU installation:
|
746.65 mm (29.39 inches) |
-23.50 mm 3 (-0.92 inches) |
Supporting PDU installation only:
|
||||
9308 | 1100 mm (43.31 inches) |
Supporting CMA and PDU installation:
|
772.50 mm (30.41 inches) |
8 mm (0.31 inches) |
Supporting PDU installation only:
|
||||
9363 | 1100 mm (43.31 inches) |
Supporting CMA and PDU installation:
|
787.50 mm (31 inches) |
11 mm (0.43 inches) |
Supporting PDU installation only:
|
||||
9360 9361 |
1200 mm (47.24 inches) |
Supporting CMA and PDU installation:
|
889.5 mm (35.02 inches) |
-6 mm 3 (-0.24 inches) |
Supporting PDU installation only:
|
||||
7D6D 7D6E |
1200 mm (47.24 inches) |
Supporting CMA and PDU installation:
|
885 mm (34.84 inches) |
7.91 mm (0.31 inches) |
Supporting PDU installation only:
|
Notes:
- 1Item A refers to the recommended distance between the front surface of the front mounting flange and the front surface of the parallel 0U PDU.
- 2 Item B refers to the distance between the left (right) side of the CMA and the right (left) side of the parallel 0U PDU.
- 3 The negative distance indicates that the CMA and the parallel 0U PDU have an overlap.
Rack cabinets with perpendicular 0U PDUs
The table below lists the rail kits that are supported in each rack cabinet when 0U PDUs are installed in an orientation that is perpendicular to the sidewalls of the cabinet (sockets facing the center of the rack). The table also lists the horizontal clearances A and B, as shown in the figure.
Figure 2. Rack cabinets with perpendicular 0U PDUs
Rack MT | Rack depth | Rail selection | A * |
---|---|---|---|
9307 | 1000 mm (39.37 inches) |
Supporting CMA and PDU installation:
|
808.65 mm (31.84 inches) |
Supporting PDU installation only:
|
|||
9308 | 1100 mm (43.31 inches) |
Supporting CMA and PDU installation:
|
850.05 mm (33.47 inches) |
Supporting PDU installation only:
|
|||
9363 | 1100 mm (43.31 inches) |
Supporting CMA and PDU installation:
|
871.67 mm (34.32 inches) |
Supporting PDU installation only:
|
|||
9360 9361 |
1200 mm (47.24 inches) |
Supporting CMA and PDU installation:
|
992.5 mm (39.07 inches) |
Supporting PDU installation only:
|
|||
7D6D 7D6E |
1200 mm (47.24 inches) |
Supporting CMA and PDU installation:
|
969.1 mm (38.15 inches) |
Supporting PDU installation only:
|
Note: * Item A refers to the recommended distance between the front surface of the front mounting flange and the side of the vertical 0U PDU.
Related product families
Product families related to this document are the following:
Help
This page provides guidance how to use the features of the Lenovo Press comparison tool.
Topics
Searching
You can use the search field either as the primary search mechanism or use it in conjunction with the advanced filters to further filter down results. The search field searches all text for matches.
Search | Purpose |
---|---|
Intel 480gb | Returns all entries that have both words, "intel" and "480gb" |
nvme available | Returns all entries that have both words, "nvme" and "available". Some comparisons include product announcement and product withdrawal data along with an availability statement. Such comparisons will allow you to therefore search on keywords "available" or "withdrawn". |
samsung or micron | Returns all entries that have either "samsung" or "micron" in them |
4XB7A08502 | Returns the entry with this part number |
4XB7A0850* | Returns all entries with a part number that starts with 4XB7A08502 (* is the wildcard character) |
hgst "2.5-inch" | Use double quotes to search for a phrase. Needed with the text includes a period or hypen |
Filtering
Filtering allows you to perform an advanced search based on specific fields (rows) of the data. All filters are logically ANDed together. Simply click the Add Filter button and select the Attribute and possible values you want.
- For text fields, either type in a text string or select one from the pulldown (you cannot select multiple)
- For numeric fields, select the operator (equals, less than, greater than, or between), then type in or select a value (or 2 values for the between operator)
- For date fields, select the operator (equals, less than, greater than, or between), then type in or select a value (or 2 values for the between operator). You can pick the dates from a calendar picker or type in the dates. The date format required is US format - mm/dd/yyyy.
To use the filter functions, do the following:
- Click the Add Filter button
- Select the attribute you want to filter on.
- If the data you want to filter on is text, you are prompted to either enter a value or you can select from the list
- If the data you want to filter on is numeric, you are prompted to specify an operator (default is =) and enter any number or select from existing values
- If the data you want to filter on is a date, you are prompted to specify an operator (default is =) and enter or select a date:
- You can add additional filters by clicking the Add Filter button. All filters are logically ANDed together.
- You can delete a filter by clicking the red X button to the right of that filter.
- Once you are ready to filter, click the Search button.
Alternatively, you can use the filter functions directly in the column headings:
Tip: The Filter menu appears at the attribute heading. By default, this is the row headings, however if you transpose the data (click the Transpose button), then the Filter menu appears in the column heading instead.
- Click the ˅ symbol in the row or column you want to filter on
- Click Filter and then select the value(s) you want shown
- Click the Filter button.
Transpose
By default, the attributes of the data are shown on the left side (row headings). If you prefer, you can transpose the data so that the attributes are along the top of the table (column headings). To do this, simply click the Transpose button.
Export
Column actions
Here are column actions you can perform.
Resizing columns
You can resize a column by simply dragging the border between two columns, just as you would in Excel.
You can also double-click, which will resize the column to the width needed to display all cells in that column in one line, just like Excel.
Rearranging columns
You can move a column left or right by simply clicking & dragging the column heading cell.
When you click and drag the column heading, the symbol appears. This indicates that where you have the cell is not (yet) a drop target:
Once you drag the cell left or right near to where you want to move the column to, the drop target appears (see the yellow highlight in the image below) and the symbol changes to a
symbol, indicating that it is a valid drop target. Release the mouse and the column moves to the new position.
Hiding columns
You can hide one or more columns by clicking the ˅ symbol in the column heading then clicking Columns. You can then deselect any columns you wish to hide (or select them to show them again)
Hiding (filtering) rows or columns
You can filter out data based on specific values of attributes by clicking the ˅ symbol in the row or column heading and clicking Filter. You can then click the values you wish to show.
Tip: The Filter menu appears at the attribute heading. By default, this is the row headings, however if you transpose the data (click the Transpose button), then the Filter menu appears in the column heading instead.
Sorting data
To sort the displayed data alphabetically based on one specific column, there are two ways:
- Click the column heading once to sort ascending or a second time to reverse the sort
- Click the ˅ symbol in that column heading and click Sort Ascending or Sort Descending
Locking a column
Highlight highest/lowest (H/L)
Highlight values different from first (≠1)
Change History
March 13, 2025
- The SE450 now supports the following rail kit:
- ThinkEdge 1000mm Friction Rail Kit v2, 4XF7A90718
February 25, 2025
- The following rail kits are now orderable
- ThinkSystem Long Travel Toolless Slide Rail Kit V4 with 1U CMA, 4XF7A97377
- ThinkSystem Long Travel Toolless Slide Rail Kit V4, 4XF7A97372
February 10, 2025
- Added the rack mount kit for the ST45 V3
- Added the following rail kits planned for February 25:
- ThinkSystem Long Travel Toolless Slide Rail Kit V4 with 1U CMA
- ThinkSystem Long Travel Toolless Slide Rail Kit V4
September 25, 2024
- Added new "Mounting type" attribute to indicate the type of rail (drop-in sliding, stab-in sliding, L-bracket static, etc)
September 17, 2024
- Added the following rail kits:
- ThinkSystem Toolless Stab-in Slide Rail Kit V3, 4XF7A99129
- ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 1U CMA, 4XF7A99130
- ThinkSystem Toolless Stab-in Slide Rail Kit V3 with 2U CMA, 4XF7A99131
September 3, 2024
- Added the following rail kits:
- ThinkSystem Toolless Slide Rail Kit V4 with 1U CMA, 4XF7A97373
- ThinkSystem Toolless Slide Rail Kit V4, 4XF7A97370
- ThinkSystem Toolless Friction Rail V4, 4XF7A97379
- ThinkSystem Advanced Toolless Slide Rail Kit V4 with 1U CMA, 4XF7A97375
- ThinkSystem Advanced Toolless Slide Rail Kit V4, 4XF7A97371
- Added the following servers:
- SR630 V4
- SD520 V4
August 13, 2024
- New rail kits:
- ThinkSystem SR780a V3 Rail Kit, Feature C2P8
June 12, 2024
- Updated the rail kit selections for rack cabinets with 0U PDUs installed - see the tables below the comparison matrix in the Rack cabinets with parallel 0U PDUs and Rack cabinets with perpendicular 0U PDUs sections.
June 4, 2024
- New rail kits:
- SR670 V2/SR675 V3 Heavy Systems Toolless Slide Rail Kit, Feature C3KA
- ThinkSystem Toolless Slide Rail Kit v2 Enhanced with 1U CMA, 4XF7A89443
May 30, 2024
- Corrections to rail lengths and distances between flanges for various rail kits
May 21, 2024
- Added the following server:
- ST50 V3
April 23, 2024
- Added the following rail kit:
- ThinkSystem Toolless Fixed Rail Kit, 4XF7A16545
April 16, 2024
- Added the following server
- ThinkSystem SD535 V3
February 20, 2024
- The {option_desc part=4M17A61253} (4M17A61253) supports the following servers installed in the ThinkSystem D3 Chassis:
- ThinkSystem SD530 V3
- ThinkSystem SD550 V3
January 29, 2024
- Added the ThinkSystem HS350X V3 L shape Rail Kit, feature code C0YA
January 10, 2024
- Added the following servers
- ThinkSystem SR250 V3
- ThinkSystem ST250 V3
November 9, 2023
- Reordered the rail kits by announcement date
- Added sections below the comparison for support with 0U PDUs
First published: October 24, 2023